Single Phase EATON 9155 UPS
9155 UPS
Single Phase EATON 9155 UPS 2
9155 with front covers removed
Single Phase EATON 9155 UPS 4
9155 family
« »
EATON 9155 UPS

The EATON 9155 UPS provides premium online backup power and scalable battery runtimes for IT and electrical engineering infrastructure in corporate, healthcare, banking and industrial applications. Packing maximum battery runtime into a very small footprint, the 9155 UPS is a complete power protection solution. The 9155 can be equipped with an integrated, customizable power distribution module that includes a maintenance bypass switch.

Features & Benefits

• Compact design with internal batteries, and build-in static and manual bypass switches, delivers a complete solution with reduced footprint and industry-leading power density.

• Delivering more real power with optimal 0,9 output power factor reduces need to oversize. With active power factor control (PFC), unbeatable 0,99 input power factor and reduced ITHD are achieved to ensure enhanced compatibility with any other upstream equipment.

• Reliable backup is further enhanced with Advanced Battery Management (ABM™) that by using an innovative three-stage battery charging system significantly extents battery lifetime.

• Highest availability and reliability is achieved with HotSync paralleling technology that enables paralleling up to four 9155 UPSs for additional capacity or redundancy.

• User-friendly LCD interface with wide range of connectivity options, makes 9155 easy to use and safe to operate.

• Innovative technology and design makes 9155 a truly sustainable solution by featuring high system efficiency and power density

EATON 9155 UPS
Power Rating 8-15 KVA
Voltage 220-230-240V
Frequency 50/60Hz
Configuration Tower
Product Series Powerware
Technical Specification for 10 & 15 kVA
POWER :
Ratings (kVA/Watts) 8,10,12 and 15 kVA at 0.9 power factor
Topology True double-conversion online UPS
ELECTRICAL INPUT :
Nominal Input Voltage 200V-240V with neutral or with optional transformer
Input Voltage Range -15%, +10% from nominal at 100% load without depleting battery
Operating Frequency 50/60 Hz (45 to 65Hz)
Input Power Factor P.F>0.99 typical, >0.96 frequency converter
Input Current Distortion 5% THD
ELECTRICAL OUTPUT :
Nominal Output Voltage 100/200, 110/220, 120/240 Vac 180° phase displacement; 120/208, 127/220 Vac 120° phase displacement
Output Voltage Regulation ±1% Static; ±5% dynamic at 100% resistive load change,<1 ms response time
Efficiency 90% typical
BATTERY :
Battery Type 9Ah, sealed, lead-acid, maintenance-free
Battery Runtime See Battery Runtime Chart
Battery Replacement Field-replaceable
Charger Default is 3.4A per battery string. Charger current is configurable from 0.5A to 25A per string with an overall maximum of 34A (limited by input current)
Start-On-Battery Start-On-Battery Allows start of UPS without utility input
GENERAL :
Diagnostics Full system self-test at startup
UPS Bypass Automatic on overload or UPS failure
Parallel for Redundancy and Capacity Yes, using Powerware Hot Sync technology
Dimensions and Weights See Model Selection Table
Overload 150% for 5 sec / 125% for 1 min (online), (Normal Operation) 110% for 10 min
CERTIFICATIONS :
Safety Certifications NOM-0190SCFI-1993, UL 1778, CSA C22.2, No. 107.3; EN 5502 Class A (CISPR22 Class A) and IEC 60950; IEC 62040-1-1
EMC Compliance IEC 62040-2, FCC Part 15, ICES-003, VCCI
Quality ISO 9001: 2000 and ISO 14001:1996
Markings UL, cUL, CSA, CE and NOM-NYCE
1. Due to continuous product improvements, program specifications are subject to change without notice.